Sciex Mass Spectrometer | X500R QTOF
Screening for unknown compounds in complex samples is difficult, but not finding them can have massive consequences on your results and your lab's reputation. High resolution LC-MS/MS can do the job, but is traditionally hard to implement for daily routine testing:
The X500R QTOF system changes all this.
With simple workflows, robust hardware, and end-to-end balanced performance, the X500R QTOF is the first high resolution LC-MS/MS system designed for routine testing to deliver exceptionally reliable results.
Take the complexity out of your data
Made for high throughput food, environment, and forensic testing labs, the X500R QTOF system was designed for performance so you can simplify screening and quantitation of unknowns in complex samples. But, it is more than just a mass spec. The X500R workflow ensures a seamless implementation for your lab. From methods to support, SCIEX has all the tools you need to maximize your success.
Key Features
Stability through long runs | Six heater drones throughout the TOF path ensure that the system maintains mass accuracy even through longer runs. |
Superior instrument uptime | Quick and easy QJet access enables fast and efficient maintenance, so your instrument is up and running virtually all the time. |
Robust ionization in complex samples | Renowned ionization performance from the Turbo V™ source is now delivered with a high-resolution accurate mass analyzer. |
Never compromise on performance | The N-optic design with 4mm orifice leading into the TOF accelerator tube delivers resolution without compromising sensitivity. |
Requires very little precious lab space | Occupies less lab space than any other HRMS on the market today (110x57x112cm). |
Key Features of the X500R System
Mass Range TOF | Up to 40 kDa. Precursor ion selection: 5-2250 m/z. |
Mass Accuracy Over Time, External | Less than 2 ppm RMS over 12 hours of LC-MS |
Ionization Sources | Turbo V ion source with Twin Sprayer ESI Probe and Twin Sprayer APCI Probe |
TOF-MS Resolution and Speed | ≥ 42,000 (FWHM) measured on the (M+6H)6+ charge isotope cluster for bovine insulin at m/z 956 |
To contact Sciex about Sciex Mass Spectrometer | X500R QTOF use Get a quote.
Screening for unknown compounds in complex samples is difficult, but not finding them can have massive consequences on your results and your lab's reputation. High resolution LC-MS/MS can do the job, but is traditionally hard to implement for daily routine testing:
The X500R QTOF system changes all this.
With simple workflows, robust hardware, and end-to-end balanced performance, the X500R QTOF is the first high resolution LC-MS/MS system designed for routine testing to deliver exceptionally reliable results.
Take the complexity out of your data
Made for high throughput food, environment, and forensic testing labs, the X500R QTOF system was designed for performance so you can simplify screening and quantitation of unknowns in complex samples. But, it is more than just a mass spec. The X500R workflow ensures a seamless implementation for your lab. From methods to support, SCIEX has all the tools you need to maximize your success.
Key Features
Stability through long runs | Six heater drones throughout the TOF path ensure that the system maintains mass accuracy even through longer runs. |
Superior instrument uptime | Quick and easy QJet access enables fast and efficient maintenance, so your instrument is up and running virtually all the time. |
Robust ionization in complex samples | Renowned ionization performance from the Turbo V™ source is now delivered with a high-resolution accurate mass analyzer. |
Never compromise on performance | The N-optic design with 4mm orifice leading into the TOF accelerator tube delivers resolution without compromising sensitivity. |
Requires very little precious lab space | Occupies less lab space than any other HRMS on the market today (110x57x112cm). |
Key Features of the X500R System
Mass Range TOF | Up to 40 kDa. Precursor ion selection: 5-2250 m/z. |
Mass Accuracy Over Time, External | Less than 2 ppm RMS over 12 hours of LC-MS |
Ionization Sources | Turbo V ion source with Twin Sprayer ESI Probe and Twin Sprayer APCI Probe |
TOF-MS Resolution and Speed | ≥ 42,000 (FWHM) measured on the (M+6H)6+ charge isotope cluster for bovine insulin at m/z 956 |
To contact Sciex about Sciex Mass Spectrometer | X500R QTOF use Get a quote.