Product characteristics |
Output signal |
switching signal; IO-Link; (configurable) |
Measuring range |
0...250 bar |
0...3620 psi |
0...25 MPa |
|
Process connection |
threaded connection G 1/4 internal thread |
|
Application |
Special feature |
Gold-plated contacts |
Measuring element |
metallic thin film cell |
Application |
for industrial applications |
Media |
liquids and gases |
Medium temperature [°C] |
-25...80 |
Min. bursting pressure |
1100 bar |
15950 psi |
110 MPa |
|
Pressure rating |
|
Vacuum resistance [mbar] |
-1000 |
Type of pressure |
relative pressure |
|
Electrical data |
Operating voltage [V] |
18...30 DC; (to SELV/PELV) |
Current consumption [mA] |
< 35 |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 0.3 |
Integrated watchdog |
yes |
|
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
|
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
150; (200 (...60 °C) 250 (...40 °C)) |
Switching frequency DC [Hz] |
< 170 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
|
Measuring/setting range |
Measuring range |
0...250 bar |
0...3620 psi |
0...25 MPa |
|
|
Factory setting / CMPT = 2 |
Set point SP |
2...250 bar |
40...3620 psi |
0.2...25 MPa |
|
Reset point rP |
1...249 bar |
20...3600 psi |
0.1...24.9 MPa |
|
Min. difference between SP and rP |
|
In steps of |
|
|
Status_B High Resolution / CMPT = 3 |
Set point SP |
2...250 bar |
30...3626 psi |
0.2...25 MPa |
|
Reset point rP |
1...249 bar |
12...3608 psi |
0.1...24.9 MPa |
|
Min. difference between SP and rP |
|
In steps of |
|
|
Accuracy / deviations |
Switch point accuracy [% of the span] |
< ± 0,5 |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span] |
< ± 0,25 |
Long-term stability [% of the span] |
< ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] |
0,2; (-25...80 °C) |
Temperature coefficient span [% of the span / 10 K] |
0,2; (-25...80 °C) |
|
Response times |
Response time [ms] |
< 3 |
Delay time programmable dS, dr [s] |
0...50 |
|
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
|
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
SIO mode |
yes |
Required master port type |
A; (when pin 2 not connected: B) |
Process data analogue |
1 |
Process data binary |
2 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Factory setting / CMPT = 2 |
400 |
Status_B High Resolution / CMPT = 3 |
598 |
PN7001 |
308 |
|
Note |
For further information please see the IODD PDF file under "Downloads" |
|
|
Factory setting / CMPT = 2 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
Min. process cycle time [ms] |
2.3 |
IO-Link resolution pressure [bar] |
1 |
IO-Link resolution pressure [MPa] |
0.1 |
IO-Link process data (cyclical) |
function |
bit length |
pressure |
14 |
binary switching information |
2 |
|
IO-Link functions (acyclical) |
application specific tag |
|
Status_B High Resolution / CMPT = 3 |
Profiles |
Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
Min. process cycle time [ms] |
3 |
IO-Link resolution pressure [bar] |
0.1 |
IO-Link resolution pressure [MPa] |
0.02 |
IO-Link process data (cyclical) |
function |
bit length |
pressure |
16 |
device status |
4 |
binary switching information |
2 |
|
IO-Link functions (acyclical) |
application specific tag |
|
Operating conditions |
Ambient temperature [°C] |
-25...80 |
Storage temperature [°C] |
-40...100 |
Protection |
IP 65; IP 67 |
|
Tests / approvals |
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
|
|
Shock resistance |
DIN EN 60068-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
20 g (10...2000 Hz) |
|
UL approval |
|
Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
|
Mechanical data |
Weight [g] |
239.2 |
Materials |
1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts) |
1.4542 (17-4 PH / 630) |
Min. pressure cycles |
100 million |
Tightening torque [Nm] |
25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
Process connection |
threaded connection G 1/4 internal thread |
Restrictor element integrated |
no (can be retrofitted) |
|
Displays / operating elements |
Display |
Display unit |
3 x LED, green (bar, psi, MPa) |
switching status |
2 x LED, yellow |
measured values |
alphanumeric display, red/green 4-digit |
|
|
Remarks |
Pack quantity |
1 pcs. |
|
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |