IFM Efector Position Sensor for Rising ...
Features:
| Product characteristics | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrical design | PNP | ||||||||||
| Output function | 3 x normally open | ||||||||||
| Dimensions [mm] | 65 x 52 x 110 | ||||||||||
| Application | |||||||||||
| Application | position feedback for seat valves and diaphragm valves; absolute distance measurement; monitoring of the valve seal | ||||||||||
| Electrical data | |||||||||||
| Operating voltage [V] | 18...36 DC | ||||||||||
| Current consumption [mA] | 42; (24 V) | ||||||||||
| Protection class | III | ||||||||||
| Reverse polarity protection | yes | ||||||||||
| Max. power-on delay time [ms] | 2000 | ||||||||||
| Outputs | |||||||||||
| Electrical design | PNP | ||||||||||
| Output function | 3 x normally open | ||||||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||||||
| Permanent current rating of switching output DC [mA] | 100 | ||||||||||
| Short-circuit protection | yes | ||||||||||
| Type of short-circuit protection | pulsed | ||||||||||
| Overload protection | yes | ||||||||||
| Detection zone | |||||||||||
| Measuring range [mm] | 0...80 | ||||||||||
| Max. target speed [m/s] | 1 | ||||||||||
| Resolution of valve stroke [mm] | 0.2 | ||||||||||
| Target |
|
||||||||||
| Software / programming | |||||||||||
| Parameter setting options | 3 switch points to be freely defined within the measuring range | ||||||||||
| Operating conditions | |||||||||||
| Ambient temperature [°C] | -25...85 | ||||||||||
| Note on ambient temperature |
|
||||||||||
| Protection | IP 65; IP 67; (only in conjunction with an installation in the valve head that provides sufficient protection against mechanical damage of the sensor) | ||||||||||
| Tests / approvals | |||||||||||
| EMC |
|
||||||||||
| Mechanical data | |||||||||||
| Weight [g] | 217.5 | ||||||||||
| Type of mounting | 3-hole flange | ||||||||||
| Dimensions [mm] | 65 x 52 x 110 | ||||||||||
| Materials | PA; TPE; PP; LCP | ||||||||||
| Displays / operating elements | |||||||||||
| Display |
|
||||||||||
| Accessories | |||||||||||
| Items supplied |
|
||||||||||
| Remarks | |||||||||||
| Pack quantity | 1 pcs. | ||||||||||
| Electrical connection - plug | |||||||||||
| Connection | Cable: 0.3 m, PVC; 5 x 0.14 mm² | ||||||||||
| Connection | Connector: 1 x M12 | ||||||||||
To contact ifm efector about IFM Efector Position Sensor for Rising Stem Valves | IX5010 use Get a quote.
Features:
| Product characteristics | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrical design | PNP | ||||||||||
| Output function | 3 x normally open | ||||||||||
| Dimensions [mm] | 65 x 52 x 110 | ||||||||||
| Application | |||||||||||
| Application | position feedback for seat valves and diaphragm valves; absolute distance measurement; monitoring of the valve seal | ||||||||||
| Electrical data | |||||||||||
| Operating voltage [V] | 18...36 DC | ||||||||||
| Current consumption [mA] | 42; (24 V) | ||||||||||
| Protection class | III | ||||||||||
| Reverse polarity protection | yes | ||||||||||
| Max. power-on delay time [ms] | 2000 | ||||||||||
| Outputs | |||||||||||
| Electrical design | PNP | ||||||||||
| Output function | 3 x normally open | ||||||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||||||
| Permanent current rating of switching output DC [mA] | 100 | ||||||||||
| Short-circuit protection | yes | ||||||||||
| Type of short-circuit protection | pulsed | ||||||||||
| Overload protection | yes | ||||||||||
| Detection zone | |||||||||||
| Measuring range [mm] | 0...80 | ||||||||||
| Max. target speed [m/s] | 1 | ||||||||||
| Resolution of valve stroke [mm] | 0.2 | ||||||||||
| Target |
|
||||||||||
| Software / programming | |||||||||||
| Parameter setting options | 3 switch points to be freely defined within the measuring range | ||||||||||
| Operating conditions | |||||||||||
| Ambient temperature [°C] | -25...85 | ||||||||||
| Note on ambient temperature |
|
||||||||||
| Protection | IP 65; IP 67; (only in conjunction with an installation in the valve head that provides sufficient protection against mechanical damage of the sensor) | ||||||||||
| Tests / approvals | |||||||||||
| EMC |
|
||||||||||
| Mechanical data | |||||||||||
| Weight [g] | 217.5 | ||||||||||
| Type of mounting | 3-hole flange | ||||||||||
| Dimensions [mm] | 65 x 52 x 110 | ||||||||||
| Materials | PA; TPE; PP; LCP | ||||||||||
| Displays / operating elements | |||||||||||
| Display |
|
||||||||||
| Accessories | |||||||||||
| Items supplied |
|
||||||||||
| Remarks | |||||||||||
| Pack quantity | 1 pcs. | ||||||||||
| Electrical connection - plug | |||||||||||
| Connection | Cable: 0.3 m, PVC; 5 x 0.14 mm² | ||||||||||
| Connection | Connector: 1 x M12 | ||||||||||
To contact ifm efector about IFM Efector Position Sensor for Rising Stem Valves | IX5010 use Get a quote.