Decorative Panel & Wall | MetecnoKasset
MetecnoKasset was the perfect choice for the Yorkshire Brewery (pictured above). With limited access for cranes and scaffolding, standard curtain wall and insulated panel systems were difficult to install. Because MetecnoKasset can be installed from inside the building, it allowed the developers to use insulated panel products without the added costs and logistics.
MetecnoKasset is available in a range of COLORBOND® colours, a palette of choice to create an inspiring interior and exterior finish.
Low & High-Rise (wind rated up to 250m)
Fast & Economical Alternative to Tilt Panel
Module Thickness | 115 mm |
Module Height | Made to measure up to 3800mm in height |
Module Width | Made to measure incorporating 1100mm wide panels |
Mass | 22.1 kg/m2 |
Acoustic Properties | Rw 25-37* |
Thermal Performance | ‘R’ Value: 4.91 W/m2K; ‘U’ Value: 0.20 m2K/W |
Module composition | Modified FM approved PIR (Fire –retardant Polyisocyanurate) panel with prefinished profiled steel skins and internal skin lined with 6mm fibre cement. |
Frame Material | Anodized or Powder coated extruded Aluminium with extruded weather seals |
Colours | Choice of any Colorbond® standard, metallic or custom colour for external skin, frame and trims. |
Finishes | Panel surface can be supplied in Plain, Fineline, Satinline or Ribbed profiles. |
*depending on system
Test and Engineering
Façade Fire Evaluation testing to NATA accreditation requirements by Exova Warringtonfire Aus. | Testing to AS 5113 according to their tendency to limit the spread of fire across their surface and between neighbouring buildings and integrates international standard test methods where practicable. |
Building performance testing in Australia to NATA accreditation requirements by Ian Bennie & Associates | Structural SLS, Air Infiltration, Water Penetration and Structural ULS test procedures and performance requirements in accordance with standard AS/NZS 4284:2008, Testing of Building Facades. Optional tests: including BMU
restraint, seismic loading and seal degradation. |
Engineering certification to the provisions of the section B1 of the Building Code of Australia and the Australian Standards by Inhabit Australasia | AS/NZS 1170.0:2002- Structural design actions – Part 0: General Principles
AS/NZS 1170.1:2002, Structural design actions – Part 1: Permanent, imposed & other actions AS/NZS 1170.2:2002, Structural design actions – Part 2: Wind actions AS/NZS 1664.1:1997, Aluminium Structures AS4100:1998, Steel Structures |
Codemark Certification | Coming Soon |
To contact Cladding Systems about Decorative Panel & Wall | MetecnoKasset use Get a quote.
MetecnoKasset was the perfect choice for the Yorkshire Brewery (pictured above). With limited access for cranes and scaffolding, standard curtain wall and insulated panel systems were difficult to install. Because MetecnoKasset can be installed from inside the building, it allowed the developers to use insulated panel products without the added costs and logistics.
MetecnoKasset is available in a range of COLORBOND® colours, a palette of choice to create an inspiring interior and exterior finish.
Low & High-Rise (wind rated up to 250m)
Fast & Economical Alternative to Tilt Panel
Module Thickness | 115 mm |
Module Height | Made to measure up to 3800mm in height |
Module Width | Made to measure incorporating 1100mm wide panels |
Mass | 22.1 kg/m2 |
Acoustic Properties | Rw 25-37* |
Thermal Performance | ‘R’ Value: 4.91 W/m2K; ‘U’ Value: 0.20 m2K/W |
Module composition | Modified FM approved PIR (Fire –retardant Polyisocyanurate) panel with prefinished profiled steel skins and internal skin lined with 6mm fibre cement. |
Frame Material | Anodized or Powder coated extruded Aluminium with extruded weather seals |
Colours | Choice of any Colorbond® standard, metallic or custom colour for external skin, frame and trims. |
Finishes | Panel surface can be supplied in Plain, Fineline, Satinline or Ribbed profiles. |
*depending on system
Test and Engineering
Façade Fire Evaluation testing to NATA accreditation requirements by Exova Warringtonfire Aus. | Testing to AS 5113 according to their tendency to limit the spread of fire across their surface and between neighbouring buildings and integrates international standard test methods where practicable. |
Building performance testing in Australia to NATA accreditation requirements by Ian Bennie & Associates | Structural SLS, Air Infiltration, Water Penetration and Structural ULS test procedures and performance requirements in accordance with standard AS/NZS 4284:2008, Testing of Building Facades. Optional tests: including BMU
restraint, seismic loading and seal degradation. |
Engineering certification to the provisions of the section B1 of the Building Code of Australia and the Australian Standards by Inhabit Australasia | AS/NZS 1170.0:2002- Structural design actions – Part 0: General Principles
AS/NZS 1170.1:2002, Structural design actions – Part 1: Permanent, imposed & other actions AS/NZS 1170.2:2002, Structural design actions – Part 2: Wind actions AS/NZS 1664.1:1997, Aluminium Structures AS4100:1998, Steel Structures |
Codemark Certification | Coming Soon |
To contact Cladding Systems about Decorative Panel & Wall | MetecnoKasset use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product