The patented method of the HydroTracer determines the absolute water content where the mass of the water is measured within the reactor.
The sample is weighed and filled into the HydroTracer’s sample tray, which is then placed in the tester’s heating chamber. The heater warms the sample to a temperature chosen by the operator, and water within the sample evaporates. The heating chamber is connected with the cooled upper reactor chamber of the HydroTracer – this is where the calcium hydride reagent is placed. The volatile water rises to the upper reactor chamber and when the humid air flows over the reagent, the gaseous water reacts with calcium hydride.
The cooled, dry air returns to the lower heating chamber and the process continues. The circulation of air through the HydroTracer is supported by natural convection, which is promoted by the unique design of the HydroTracer; even hygroscopic materials are completely dried with the analyzer. The final concentration of hydrogen in the reactor is proportional to the water content of the sample before the measurement. The whole operation process is controlled by PC-based software and the results calculated for the operator.
Principle of Operation
Common Applications
To contact Test Machines Australia about Tinius Olsen Moisture Analyser | HydroTracer use Get a quote.
The patented method of the HydroTracer determines the absolute water content where the mass of the water is measured within the reactor.
The sample is weighed and filled into the HydroTracer’s sample tray, which is then placed in the tester’s heating chamber. The heater warms the sample to a temperature chosen by the operator, and water within the sample evaporates. The heating chamber is connected with the cooled upper reactor chamber of the HydroTracer – this is where the calcium hydride reagent is placed. The volatile water rises to the upper reactor chamber and when the humid air flows over the reagent, the gaseous water reacts with calcium hydride.
The cooled, dry air returns to the lower heating chamber and the process continues. The circulation of air through the HydroTracer is supported by natural convection, which is promoted by the unique design of the HydroTracer; even hygroscopic materials are completely dried with the analyzer. The final concentration of hydrogen in the reactor is proportional to the water content of the sample before the measurement. The whole operation process is controlled by PC-based software and the results calculated for the operator.
Principle of Operation
Common Applications