High Resolution Horizontal Push Rod ...
Packed with new automated features, the DIL 831 features the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.
An instrument offering scientists the ideal tool for R&D laboratories to measure the linear thermal expansion and to calculate the Coefficient of Thermal Expansion (CTE) of ceramics, glasses, high performance materials, polymers, metals and alloys with great accuracy. Features include:
Measurement Principle
The single sample horizontal push rod design is the most widely used technique to measure and determine a number of parameters key for the R&D, QC and production laboratories. It is used to study density changes and phase transitions, the influence of additives and the mixing of different raw materials, measure the Glass Transition Temperature (Tg) and Volumetric Expansion.
In this technique the specimen rests on a sample support that is contained in a sample holder, and a load is applied through a push-rod to maintain it in mechanical contact with the measuring system while it is subjected to a thermal treatment. Depending upon the temperature range, the material of the measuring system and sample holder can be of fused silica, alumina or graphite.
In the DIL 831, the dimensional changes are detected and measured by an innovative incremental optical encoder with a true resolution of 1 nm
In horizontal dilatometry a critical feature is the load applied on to the sample , especially in case of unknown, difficult or fast shrinking materials as, often, R&D laboratories are required to test. The correct load varies dependent upon the events to be measured, the rate at which they occur, the time, and the experiment’s temperature range. The DIL 831 linear magnetic motor ensures a very precise and truly constant load ranging from 0.01 to 1.0N across its entire measuring range of 5000μm.
Applications
Materials
polymers, ceramics, glasses, building materials, high performance materials, metals, alloys. Ideal to be used joined to Laser Flash instrumentation
Industries
Academia, Advanced Ceramics, Building Materials, Glass, Automotive, Aerospace, Defense, Metals and non-metals Industry, Electronics and micro-electronics, Renewable energies
Specifications
Dilatometer type | Single sample horizontal push rod | |
Sample dimension length / diameter |
0 to 25 mm / 12 mm | |
Material of sample holder: | Fused silica, Al2O3 | |
Contact Force: | 0.01 – 1.0 N, linear motor controlled constant sample load | |
Change of length range: | 5000 µm | |
Resolution ΔL, ΔT: | 1 nm, 0.05°C | |
Accuracy in α: | 0.03 x 10-6 K-1 | |
Atmosphere: | Vacuum, Inert gas, Air
atmosphere control through optional gas unit with massflow controller and vacuum unit |
|
Temperature range: | RT – 1100°C RT – 1500°C RT – 1700°C |
|
Heating rate | 50°K/min | |
Cooling rates | 1100°C – RT: minimum 13 min 1500°C – RT: less than one hour 1700°C – RT: approximately one hour |
To contact TA Instruments about High Resolution Horizontal Push Rod Dilatometer | DIL 831 use Get a quote.
Packed with new automated features, the DIL 831 features the patented 1 nm resolution optical encoder, a family of new dynamic furnaces, and the new linear sample load motor. The result is the best performing horizontal single sample push-rod dilatometer available on the market.
An instrument offering scientists the ideal tool for R&D laboratories to measure the linear thermal expansion and to calculate the Coefficient of Thermal Expansion (CTE) of ceramics, glasses, high performance materials, polymers, metals and alloys with great accuracy. Features include:
Measurement Principle
The single sample horizontal push rod design is the most widely used technique to measure and determine a number of parameters key for the R&D, QC and production laboratories. It is used to study density changes and phase transitions, the influence of additives and the mixing of different raw materials, measure the Glass Transition Temperature (Tg) and Volumetric Expansion.
In this technique the specimen rests on a sample support that is contained in a sample holder, and a load is applied through a push-rod to maintain it in mechanical contact with the measuring system while it is subjected to a thermal treatment. Depending upon the temperature range, the material of the measuring system and sample holder can be of fused silica, alumina or graphite.
In the DIL 831, the dimensional changes are detected and measured by an innovative incremental optical encoder with a true resolution of 1 nm
In horizontal dilatometry a critical feature is the load applied on to the sample , especially in case of unknown, difficult or fast shrinking materials as, often, R&D laboratories are required to test. The correct load varies dependent upon the events to be measured, the rate at which they occur, the time, and the experiment’s temperature range. The DIL 831 linear magnetic motor ensures a very precise and truly constant load ranging from 0.01 to 1.0N across its entire measuring range of 5000μm.
Applications
Materials
polymers, ceramics, glasses, building materials, high performance materials, metals, alloys. Ideal to be used joined to Laser Flash instrumentation
Industries
Academia, Advanced Ceramics, Building Materials, Glass, Automotive, Aerospace, Defense, Metals and non-metals Industry, Electronics and micro-electronics, Renewable energies
Specifications
Dilatometer type | Single sample horizontal push rod | |
Sample dimension length / diameter |
0 to 25 mm / 12 mm | |
Material of sample holder: | Fused silica, Al2O3 | |
Contact Force: | 0.01 – 1.0 N, linear motor controlled constant sample load | |
Change of length range: | 5000 µm | |
Resolution ΔL, ΔT: | 1 nm, 0.05°C | |
Accuracy in α: | 0.03 x 10-6 K-1 | |
Atmosphere: | Vacuum, Inert gas, Air
atmosphere control through optional gas unit with massflow controller and vacuum unit |
|
Temperature range: | RT – 1100°C RT – 1500°C RT – 1700°C |
|
Heating rate | 50°K/min | |
Cooling rates | 1100°C – RT: minimum 13 min 1500°C – RT: less than one hour 1700°C – RT: approximately one hour |
To contact TA Instruments about High Resolution Horizontal Push Rod Dilatometer | DIL 831 use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product