Surge Diverters | E40/280 & E40/280/NONC
Features
- Designed for DIN rail mount
- Failure indicator
- Dry contacts for remote sensing
- Complies with AS 1768 & IEC 1312-3
- Part No. E40/280 - Basic model
- Part No. E40/280/NONC - Remote sense contacts
Surge diverters are installed in parallel, preferably after the main switch and before any earth leakage units. They are connected from one phase to a solid ground at the power inlet, thus protecting any equipment down stream. Surge Diverters soak up any spikes that come in on the 240Vac line, either Lightening induced or Electrically induced, eg "spot welders" or "motor starters".
There are 2 models available, both constructed from electrical grade plastic with a case that is designed to be DIN rail mounted, both with MOV modules inside for circuit protection and a fused mechanical disconnect. In the disconnect condition a flag colour change appears at the "indicator window" and the exhausted unit is disconnected from the circuit. At this stage the unit should be replaced, as it offers no protection.
The basic model offers an "indicator window" showing unit status, "OK" or "REPLACE" and the unit automatically disconnects on "REPLACE" condition.
The remote-sensing model offers an "indicator window" showing unit status, "OK" or "REPLACE" and the unit automatically disconnects on "REPLACE" condition. In addition there are a set of dry contacts on this unit, used for remote sensing, They can indicate either, healthy or replace depending on requirements. The contacts give N/O or N/C options and can be used to check unit status, either by PLC alarm or indicator lights if a change occurs in the condition of the surge diverter. Max. Current on the contacts is 1A/240Vac or 500mA at DC.
Both units are rated at 40kA but other sizes are also available. IEEE considers lightening strikes induce a maximum of 10kA inside buildings. 40kA metal oxide protection will offer reliable protection with extra margin.
Technical Specifications - General Static conditions @ 25°C Mains 230/240 Vac Max continuous voltage (per phase) 280 V rms (350 Vdc) Typical earth leakage current (per phase) <1mA Operating temperature -10°C to +55°C Typical capacitance 2700pF Transient conditions @ 25°C Max voltage withstand (1.2/50µS) >10kV Max current withstand (8/20µS) 40 kA Max energy withstand (2µS) 550 joules Max clamping voltage 710 V Typical response time <25 nS Size Standard DIN 17.5mm wide
Part No. E40/280 Gray Body Window Code With failure indicator window Gray = OK No remote sensing contacts Black = Replace Part No. E40/280/NONC Red Body Window Code With failure indicator window Red = OK Remote sensing contacts White = Replace Remote sensing contacts code OK Failed (Replace) Contacts Max. 1A/250VAC
To contact Dyne Industries about Surge Diverters | E40/280 & E40/280/NONC use Get a quote.
Features
- Designed for DIN rail mount
- Failure indicator
- Dry contacts for remote sensing
- Complies with AS 1768 & IEC 1312-3
- Part No. E40/280 - Basic model
- Part No. E40/280/NONC - Remote sense contacts
Surge diverters are installed in parallel, preferably after the main switch and before any earth leakage units. They are connected from one phase to a solid ground at the power inlet, thus protecting any equipment down stream. Surge Diverters soak up any spikes that come in on the 240Vac line, either Lightening induced or Electrically induced, eg "spot welders" or "motor starters".
There are 2 models available, both constructed from electrical grade plastic with a case that is designed to be DIN rail mounted, both with MOV modules inside for circuit protection and a fused mechanical disconnect. In the disconnect condition a flag colour change appears at the "indicator window" and the exhausted unit is disconnected from the circuit. At this stage the unit should be replaced, as it offers no protection.
The basic model offers an "indicator window" showing unit status, "OK" or "REPLACE" and the unit automatically disconnects on "REPLACE" condition.
The remote-sensing model offers an "indicator window" showing unit status, "OK" or "REPLACE" and the unit automatically disconnects on "REPLACE" condition. In addition there are a set of dry contacts on this unit, used for remote sensing, They can indicate either, healthy or replace depending on requirements. The contacts give N/O or N/C options and can be used to check unit status, either by PLC alarm or indicator lights if a change occurs in the condition of the surge diverter. Max. Current on the contacts is 1A/240Vac or 500mA at DC.
Both units are rated at 40kA but other sizes are also available. IEEE considers lightening strikes induce a maximum of 10kA inside buildings. 40kA metal oxide protection will offer reliable protection with extra margin.
Technical Specifications - General Static conditions @ 25°C Mains 230/240 Vac Max continuous voltage (per phase) 280 V rms (350 Vdc) Typical earth leakage current (per phase) <1mA Operating temperature -10°C to +55°C Typical capacitance 2700pF Transient conditions @ 25°C Max voltage withstand (1.2/50µS) >10kV Max current withstand (8/20µS) 40 kA Max energy withstand (2µS) 550 joules Max clamping voltage 710 V Typical response time <25 nS Size Standard DIN 17.5mm wide
Part No. E40/280 Gray Body Window Code With failure indicator window Gray = OK No remote sensing contacts Black = Replace Part No. E40/280/NONC Red Body Window Code With failure indicator window Red = OK Remote sensing contacts White = Replace Remote sensing contacts code OK Failed (Replace) Contacts Max. 1A/250VAC