Parker Domnick Hunter Oil/Water Separators ...
Oil/water separators are installed as part of the compressed air purification system and are designed to reduce the oil concentration in the collected condensate.
The oily condensate that is removed from the compressed air system cannot be discharged directly to the foul sewer without the oil content being reduced to within legal disposal limits.
By reducing the oil concentration in water to permitted levels, discharge can be safely directed to the foul sewer meaning large volumes of clean water, up to 99.9% of the total condensate, can be safely disposed of. This leaves a relatively small amount of concentrated oil to be disposed of legitimately and economically.
Oily condensate from the compressed air system enters the ES2000 Series oil/water separator under pressure, and is allowed to expand in the specially designed centrifugal inlet chamber. During a six stage process, the water and oil are separated, allowing the cleaned water to be safely discharged to the foul sewer through the outlet, whilst the drained oil is collected in an external oil container where it can be disposed of according to legal requirements.
Features
Technical Specifications
To contact Parker Hannifin about Parker Domnick Hunter Oil/Water Separators | ES2000 Series use Get a quote.
Oil/water separators are installed as part of the compressed air purification system and are designed to reduce the oil concentration in the collected condensate.
The oily condensate that is removed from the compressed air system cannot be discharged directly to the foul sewer without the oil content being reduced to within legal disposal limits.
By reducing the oil concentration in water to permitted levels, discharge can be safely directed to the foul sewer meaning large volumes of clean water, up to 99.9% of the total condensate, can be safely disposed of. This leaves a relatively small amount of concentrated oil to be disposed of legitimately and economically.
Oily condensate from the compressed air system enters the ES2000 Series oil/water separator under pressure, and is allowed to expand in the specially designed centrifugal inlet chamber. During a six stage process, the water and oil are separated, allowing the cleaned water to be safely discharged to the foul sewer through the outlet, whilst the drained oil is collected in an external oil container where it can be disposed of according to legal requirements.
Features
Technical Specifications