FLIR Optical Gas Imaging Cameras | GF620
With the GF620’s ground-breaking 640 × 480 IR detector, inspectors can safely scan for gases from greater distances than with previous, lower-resolution models. It’s also the first FLIR optical gas imaging camera to offer a Quantification mode (Q-Mode), for streamlined set-up of the
optional QL320 gas quantification system. The durable GF620 has an ergonomic design that reduces strain, with a tiltable viewfinder and adjustable LCD monitor for viewing at any angle.
INCREASE SURVEY EFFICIENCY
Inspect up to nine-times faster than with traditional methods, without halting operations
• Sweep wide areas, then narrow in to rapidly scan components for signs of leaks
• See smaller leaks using the same optics and distances as earlier models, thanks to a 4x increase in pixels within the field of view • Use temperature measurement to ensure optimal contrast between gases and the background
• Improve detection by engaging High Sensitivity Mode (HSM) to accentuate plume movement
SAVE PRODUCT AND REVENUE
Catch leaks early, reduce emissions, and avoid the cost of gas losses and regulatory fines
• Eliminate the guesswork that delays repairs by pinpointing the exact source of emissions
• Improve reliability and avoid product loss by surveying for leaks while equipment is operating
• Quantify your losses and their effect on the bottom line by engaging Q-mode*
• Verify regulatory compliance and meet sensitivity standards defined in the US EPA’s OOOOa methane rule and Method 21 AWP
LESS FATIGUE, MORE SAFETY
Survey more components for longer periods, while maintaining a safe distance
• Inspect all day long with less fatigue thanks to tiltable eyepiece, adjustable LCD screen, and other ergonomic features
• Reduce exposure to harmful emissions by verifying the presence of gas from a safe distance
• Quickly set up and run Q-Mode without the need to tether to the optional QL320 system
• Confirm the size of leaks when surveying hard-to-reach or hard-to-measure components
SPECIFICATIONS | |
Image and optical data | GF620 |
IR resolution | 640 × 480 (307,200 pixels) |
Thermal sensitivity | 30 mK at 30°C (86°F) |
Field of view | 24° x 18° or 14.5° x 10.8° |
Minimum focus distance | 0.3 m (1.0 ft) |
Focal length | 23 mm (0.89 in) or 38 mm (1.49 in) |
F-number | 1.59 |
Focus | Manual |
Zoom | 1-8x continuous, digital zoom |
Detector data | |
Detector type and pitch | Indium antimonide (InSb) focal plane array; 15 μm |
Spectral range | 3.2–3.4 μm |
Sensor cooling | Sterling microcooler |
Image presentation and frame rate | |
Full frame rate | 60 Hz |
Display | 800 × 480 pixel built-in, 4.3 in widescreen LCD |
Viewfinder | 800 × 480 pixel built-in, tiltable OLED |
Automatic image adjustment | Continuous/manual, linear- or histogram-based |
Manual image adjustment | Level/span |
Image modes | IR image, visual image, High Sensitivity Mode (HSM) |
Color palettes | Iron, gray, rainbow, rainbow HC, arctic, lava |
Measurement and analysis | |
Temperature range | -20°C to 350°C (-4°F to 662°F) |
Accuracy | ±1°C for temperature range (0°C to 100°C) or ±2% of reading for temperature range |
Detected gases | Includes: methane, propane, benzene, butane, ethanol,ethane, ethylene, ethylbenzene, heptane, hexane, isoprene, methanol, MEK, MIBK, octane, pentane, 1-pentene, propylene, toluene, xylene |
Spotmeters / area boxes | 10 spotmeters; 5 boxes with max/min/average |
Measurement corrections | Reflected temperature, distance, atmospheric transmission,humidity, external optics |
Emissivity correction | Variable from 0.01 to 1.0 or selected from editablen materials list |
To contact Teledyne FLIR about FLIR Optical Gas Imaging Cameras | GF620 use Get a quote.
With the GF620’s ground-breaking 640 × 480 IR detector, inspectors can safely scan for gases from greater distances than with previous, lower-resolution models. It’s also the first FLIR optical gas imaging camera to offer a Quantification mode (Q-Mode), for streamlined set-up of the
optional QL320 gas quantification system. The durable GF620 has an ergonomic design that reduces strain, with a tiltable viewfinder and adjustable LCD monitor for viewing at any angle.
INCREASE SURVEY EFFICIENCY
Inspect up to nine-times faster than with traditional methods, without halting operations
• Sweep wide areas, then narrow in to rapidly scan components for signs of leaks
• See smaller leaks using the same optics and distances as earlier models, thanks to a 4x increase in pixels within the field of view • Use temperature measurement to ensure optimal contrast between gases and the background
• Improve detection by engaging High Sensitivity Mode (HSM) to accentuate plume movement
SAVE PRODUCT AND REVENUE
Catch leaks early, reduce emissions, and avoid the cost of gas losses and regulatory fines
• Eliminate the guesswork that delays repairs by pinpointing the exact source of emissions
• Improve reliability and avoid product loss by surveying for leaks while equipment is operating
• Quantify your losses and their effect on the bottom line by engaging Q-mode*
• Verify regulatory compliance and meet sensitivity standards defined in the US EPA’s OOOOa methane rule and Method 21 AWP
LESS FATIGUE, MORE SAFETY
Survey more components for longer periods, while maintaining a safe distance
• Inspect all day long with less fatigue thanks to tiltable eyepiece, adjustable LCD screen, and other ergonomic features
• Reduce exposure to harmful emissions by verifying the presence of gas from a safe distance
• Quickly set up and run Q-Mode without the need to tether to the optional QL320 system
• Confirm the size of leaks when surveying hard-to-reach or hard-to-measure components
SPECIFICATIONS | |
Image and optical data | GF620 |
IR resolution | 640 × 480 (307,200 pixels) |
Thermal sensitivity | 30 mK at 30°C (86°F) |
Field of view | 24° x 18° or 14.5° x 10.8° |
Minimum focus distance | 0.3 m (1.0 ft) |
Focal length | 23 mm (0.89 in) or 38 mm (1.49 in) |
F-number | 1.59 |
Focus | Manual |
Zoom | 1-8x continuous, digital zoom |
Detector data | |
Detector type and pitch | Indium antimonide (InSb) focal plane array; 15 μm |
Spectral range | 3.2–3.4 μm |
Sensor cooling | Sterling microcooler |
Image presentation and frame rate | |
Full frame rate | 60 Hz |
Display | 800 × 480 pixel built-in, 4.3 in widescreen LCD |
Viewfinder | 800 × 480 pixel built-in, tiltable OLED |
Automatic image adjustment | Continuous/manual, linear- or histogram-based |
Manual image adjustment | Level/span |
Image modes | IR image, visual image, High Sensitivity Mode (HSM) |
Color palettes | Iron, gray, rainbow, rainbow HC, arctic, lava |
Measurement and analysis | |
Temperature range | -20°C to 350°C (-4°F to 662°F) |
Accuracy | ±1°C for temperature range (0°C to 100°C) or ±2% of reading for temperature range |
Detected gases | Includes: methane, propane, benzene, butane, ethanol,ethane, ethylene, ethylbenzene, heptane, hexane, isoprene, methanol, MEK, MIBK, octane, pentane, 1-pentene, propylene, toluene, xylene |
Spotmeters / area boxes | 10 spotmeters; 5 boxes with max/min/average |
Measurement corrections | Reflected temperature, distance, atmospheric transmission,humidity, external optics |
Emissivity correction | Variable from 0.01 to 1.0 or selected from editablen materials list |
To contact Teledyne FLIR about FLIR Optical Gas Imaging Cameras | GF620 use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product