Bestech Current and Voltage Calibrators ...
Model 4411 from Burster is used to simulate a transducer, measures voltage up to 30VDC and currents up to 24mA and is capable as a small manageable checking and calibration device for process technology in field. The portable calibration device has many other applications in the metrology including:
The function SINK can simulate a 2 wire transducer in a current loop. The output level can be changed between 4, 8, 12, 16 and 20 mA signals by one touch for the “4-20 mA” output, and between 1, 2, 3, 4 and 5 V DC signals for the “1-5 V” output, for efficient calibration work. While the “ramp function” increases and decreases the output level to the present level at a constant rate for the selected sweep time (16 or 32 seconds).DIGISTANT® model 4462 can be used either as a standalone table-top device, or in automatic, computer assisted manufacturing and testing systems. Its applications include:
Products | Measuring ranges | Accuracy | Temperature | Traits |
---|---|---|---|---|
High precision Calibration Source DIGISTANT®Model 4462 | ±30V(±60V); ±52mA(±22mA); Thermocouple: 14 types | 0.003% Rdg. (error limit) | 5?..23?..40? | – Simulation for all conventional thermocouple types; – Standard with RS232 & IEEE488 interface, USB and Ethernet; – Current “SINK”. |
To contact Bestech Australia about Bestech Current and Voltage Calibrators | DIGISTANT 4411 use Get a quote.
Model 4411 from Burster is used to simulate a transducer, measures voltage up to 30VDC and currents up to 24mA and is capable as a small manageable checking and calibration device for process technology in field. The portable calibration device has many other applications in the metrology including:
The function SINK can simulate a 2 wire transducer in a current loop. The output level can be changed between 4, 8, 12, 16 and 20 mA signals by one touch for the “4-20 mA” output, and between 1, 2, 3, 4 and 5 V DC signals for the “1-5 V” output, for efficient calibration work. While the “ramp function” increases and decreases the output level to the present level at a constant rate for the selected sweep time (16 or 32 seconds).DIGISTANT® model 4462 can be used either as a standalone table-top device, or in automatic, computer assisted manufacturing and testing systems. Its applications include:
Products | Measuring ranges | Accuracy | Temperature | Traits |
---|---|---|---|---|
High precision Calibration Source DIGISTANT®Model 4462 | ±30V(±60V); ±52mA(±22mA); Thermocouple: 14 types | 0.003% Rdg. (error limit) | 5?..23?..40? | – Simulation for all conventional thermocouple types; – Standard with RS232 & IEEE488 interface, USB and Ethernet; – Current “SINK”. |
To contact Bestech Australia about Bestech Current and Voltage Calibrators | DIGISTANT 4411 use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product